Calibration History

Prairie View Dairy

Review calibration evidence, measured accuracy, certificates, technicians, and upcoming service requirements for carbon-supporting equipment at Prairie View Dairy.

Current coverage 75.0%6 of 8 assets currentCertificate history · Due-date control

Calibration position

Equipment with calibration records
TOTAL ASSETS
8
equipment with calibration records
CURRENT
6
passing and within calibration period
DUE SOON
0
due within 30 days
OVERDUE
2
assets requiring immediate review
CALIBRATION ASSURANCE

Measurement confidence

Current calibration coverage and upcoming service state for equipment supporting carbon-accounting measurements.

COVERAGE

Current asset coverage

latest calibration: Jul 22, 2026 12:00 AM
75.0% CURRENT
ASSURANCE COVERAGE 6 of 8

Share of monitored equipment with passing calibration inside the active calibration window.

Latest Calibration Jul 22, 2026 12:00 AM
READINESS

Calibration status

✓
Calibration records available 8 assets represented
!
No overdue calibrations 2 assets overdue
✓
Upcoming calibration schedule 0 assets due within 30 days
!
Full calibration coverage 6 of 8 assets current
ASSURANCE FLOW

Measurement to evidence

Calibration converts an instrument reading into traceable evidence suitable for downstream carbon accounting.

01 Instrument flow meter or monitored asset
→
02 Calibration technician + measured accuracy
→
03 Certificate traceable service evidence
→
04 Data Quality measurement confidence
→
05 Carbon Evidence defensible accounting input
CALIBRATION RECORDS

Equipment calibration history

Accuracy changes, results, technicians, certificates, next-due dates, and current status.

RECORDS 8
LATEST Jul 22, 2026 12:00 AM
COVERAGE 75.0%
Current
CALIBRATION DATE Jul 22, 2026 12:00 AM
RESULT PASS
PREVIOUS ACCURACY Not recorded
MEASURED ACCURACY Not recorded
TECHNICIAN Alex Rivera
NEXT DUE Jul 22, 2027
CERTIFICATE CAL-MP-003-2026
NOTES

Pump speed, flow, pressure, and energy draw checked.

Current
CALIBRATION DATE Jul 22, 2026 12:00 AM
RESULT PASS
PREVIOUS ACCURACY Not recorded
MEASURED ACCURACY Not recorded
TECHNICIAN Alex Rivera
NEXT DUE Jul 22, 2027
CERTIFICATE CAL-MP-004-2026
NOTES

Pump speed, flow, pressure, and energy draw checked.

Current
CALIBRATION DATE Jul 7, 2026 12:00 AM
RESULT PASS
PREVIOUS ACCURACY 0.3000%
MEASURED ACCURACY 0.2500%
TECHNICIAN Morgan Patel
NEXT DUE Jul 4, 2027
CERTIFICATE CAL-MFM-003-IN-2026
NOTES

Flow meter verified using timed-volume comparison.

Overdue
CALIBRATION DATE Jul 7, 2026 12:00 AM
RESULT RECALIBRATION_DUE
PREVIOUS ACCURACY 0.3000%
MEASURED ACCURACY 0.2500%
TECHNICIAN Morgan Patel
NEXT DUE Sep 25, 2026
CERTIFICATE CAL-MFM-003-OUT-2026
NOTES

Outlet meter calibration is overdue and contributes to Prairie View review status.

Current
CALIBRATION DATE Jul 7, 2026 12:00 AM
RESULT PASS
PREVIOUS ACCURACY 0.3500%
MEASURED ACCURACY 0.3000%
TECHNICIAN Morgan Patel
NEXT DUE Jul 3, 2027
CERTIFICATE CAL-MFM-004-IN-2026
NOTES

Flow meter verified using timed-volume comparison.

Current
CALIBRATION DATE Jul 7, 2026 12:00 AM
RESULT PASS
PREVIOUS ACCURACY 0.3500%
MEASURED ACCURACY 0.3000%
TECHNICIAN Morgan Patel
NEXT DUE Jul 3, 2027
CERTIFICATE CAL-MFM-004-OUT-2026
NOTES

Flow meter verified using timed-volume comparison.

Current
CALIBRATION DATE Jul 2, 2026 12:00 AM
RESULT PASS
PREVIOUS ACCURACY 0.1500%
MEASURED ACCURACY 0.1000%
TECHNICIAN Jordan Lee
NEXT DUE Jun 29, 2027
CERTIFICATE CAL-MLS-003-2026
NOTES

Level sensor verified against manual tank-depth measurement.

Overdue
CALIBRATION DATE Jul 2, 2026 12:00 AM
RESULT RECALIBRATION_DUE
PREVIOUS ACCURACY 0.2000%
MEASURED ACCURACY 0.1500%
TECHNICIAN Jordan Lee
NEXT DUE Sep 28, 2026
CERTIFICATE CAL-MLS-004-2026
NOTES

Calibration has passed its scheduled due date; maintenance review required.